logo
Wyślij wiadomość
Do domu > produkty > Czujnik ciśnienia HVAC >
WNK 4~20mA 0.5-4.5V Refrigerant Pressure Sensor for R410a R22 R134a R404a

WNK 4~20mA 0.5-4.5V Refrigerant Pressure Sensor for R410a R22 R134a R404a

R410a refrigerant pressure sensor

4-20mA HVAC pressure sensor

R134a compatible pressure transducer

Miejsce pochodzenia:

Anhui, Chiny

Nazwa handlowa:

WNK

Orzecznictwo:

CE, ROHS

Numer modelu:

WNK80MA

Skontaktuj się z nami
Poproś o wycenę
Szczegóły produktu
Gwarancja:
1 rok
Aplikacja:
Klimatyzacja Czynnik chłodniczy Hvac
Klasa ochrony:
IP65 /67
Wyjście:
4-20 mA, 0-5 V, 1-5 V, 0,5-4,5 V, 0-10 V
Materiał obudowy:
304SS, 316L, 316SS
Zmierzone media:
Ciecz, gaz, para, olej, powietrze
Serwis OEM:
OEM, ODM, dostępne dostosowanie
Zasilanie:
5 V prądu stałego, 12–32 V prądu stałego
Zakres ciśnienia::
0-15 MPa
Temperatura robocza::
-40~85 ℃
Dokładność:
0,5% FS 1% FS
Port:
Szanghaj/Ningbo
Podkreślić:

R410a refrigerant pressure sensor

,

4-20mA HVAC pressure sensor

,

R134a compatible pressure transducer

Warunki płatności i wysyłki
Minimalne zamówienie
1 szt
Cena
$19.00/Pieces 1-49 Pieces
Szczegóły pakowania
100 sztuk w kartonie zbiorczym
Czas dostawy
5-8 DNI ROBOCZYCH
Zasady płatności
T/T, Western Union, Moneygr, PayPal
Możliwość Supply
5000 sztuk/sztuk na miesiąc Czujnik ciśnienia do klimatyzacji
Opis produktu
 

What role does the sensor play in the air compressor?

The compressor (compressor), as the heart of the refrigeration system, is a driven fluid machine that lifts low-pressure gas into high-pressure gas. The low-temperature and low-pressure refrigerant gas sucked from the suction pipe is compressed by the rotation of the motor to discharge the high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle. Thus, a refrigeration cycle of compression → condensation (exotherm) → expansion → evaporation (heat absorption) is realized. The compressor is divided into piston compressor, screw compressor, centrifugal compressor, linear compressor and so on.
During the work, the actual responsibility of the compressor is to increase the pressure and increase the state of the suction pressure to the state of the exhaust pressure. Compression ratio is a technical expression of pressure difference, which means the absolute pressure on the high pressure side divided by the absolute pressure on the low pressure side. The compression ratio must be calculated using an absolute pressure value. In order to avoid making the calculated value of the compression ratio negative, the absolute pressure must be used instead of the gauge pressure when calculating the pressure ratio. It makes sense to use an absolute pressure value to make the compression ratio calculation a positive value
 
WNK 4~20mA 0.5-4.5V Refrigerant Pressure Sensor for R410a R22 R134a R404a 0
WNK 4~20mA 0.5-4.5V Refrigerant Pressure Sensor for R410a R22 R134a R404a 1
WNK 4~20mA 0.5-4.5V Refrigerant Pressure Sensor for R410a R22 R134a R404a 2
Large central air conditioning, refrigeration equipment, in order to achieve automatic control of the machine, the lowest energy consumption ratio, the operation of the equipment needs to be fully monitored, such as temperature, refrigeration medium pressure.
The pressure sensor mainly measures the pressure of the refrigerating medium online on the refrigerating equipment, and transmits the pressure to the control system of the main machine in the form of electrical signals, so as to reflect the compression operation state of the equipment, to realize the automatic control of the product, and to reflect the consumption of the equipment as soon as possible.

Wyślij do nas zapytanie

Polityka prywatności Chiny Dobra jakość Elektroniczny czujnik ciśnienia Sprzedawca. 2021-2025 Hefei WNK Smart Technology Co.,Ltd Wszystkie prawa zastrzeżone.